Product photographs of the Two Stage Blower Three Phase present the 2XGB 420A41 model - a heavy-duty dual-impeller vortex pump designed for three-phase factory environments. Real-shot images display the complete unit from multiple viewing angles, with the cast aluminum alloy housing, threaded flange air ports, and three-phase junction box all clearly visible. Internal structure cutaways expose the series-mounted dual impellers, the 100% pure copper coil motor winding with its characteristic bright copper color, and the C&U sealed bearings supporting the rotor shaft at both ends. Material detail close-ups highlight the precision-machined flange faces, the rubber-gasketed pump body seal, the sound-absorbing silencer material, and the reinforced steel mounting base plate. The performance data sheet specifies 150 cubic meters per hour of airflow, -280 mbar maximum vacuum, and 290 mbar discharge pressure at 50Hz from a 2.2 kW motor. Application scenario images illustrate the blower in bottle drying lines using air knife technology, car wash drying stations, and post-wash moisture removal systems. For factories running on three-phase power where oil-free high-pressure air is essential, the Two Stage Blower Three Phase delivers the pneumatic reliability industrial production demands.









Twin impeller vortex fan parameter table & complete machine installation dimensions explanation
- Twin impeller vortex fan performance parameter table
|
Product Name |
2XGB 420A41 Double Stage Vortex Air Pump |
|
Frequency |
50Hz / 60Hz |
|
Rated Power |
2.2 kW / 2.55 kW |
|
Output Voltage |
220-240 V |
|
Rated Current |
10 A / 10 A |
|
Max Air Flow |
150 m³/h / 180 m³/h |
|
Max Vacuum |
-280 mbar / -260 mbar |
|
Max Pressure |
290 mbar / 280 mbar |
|
Noise |
66 dB(A) / 69 dB(A) |
|
Weight |
27 Kg |

- Twin impeller vortex fan installation dimensions explanation



Application scenarios introduction
Post-wash moisture removal is a common bottleneck in production lines, which our blowers solve using "dry air knife" technology. In "bottle drying" systems for the beverage industry and "car wash dry" facilities, the blower generates a powerful air stream that shears water droplets from surfaces instantly. This process is highly effective for preparing metal parts for painting or electronics for assembly. Because the air is 100% oil-free, it leaves no residue on glass, metal, or plastic, ensuring a pristine finish. The blower's thermal endurance allows it to work in tandem with heaters for "forced drying" tunnels, maintaining high throughput for 24-hour manufacturing shifts.








Custom processing workflow

Packaging and transportation

Factory introduction







FAQ
1. Q: How quiet is a 2.2kW double-stage blower?
A: Our XGB 420H46 model runs at approximately 66-69 dB, which is very quiet for its power level.
2. Q: Does the blower vibrate heavily during operation?
A: No, the dynamic balancing of the impellers and the shock-proof base ensure very low mechanical vibration.
3. Q: What is the maximum ambient temperature for operation?
A: We recommend an ambient temperature of ≤50°C to ensure optimal cooling of the motor and housing.
4. Q: How does the blower dissipate heat?
A: Through integrated radial fins on the pump and longitudinal fins on the motor, supported by an external cooling fan.
5. Q: Is the airflow pulsing or steady?
A: The side-channel principle delivers a smooth, non-pulsing stream of air, ideal for sensitive printing and drying.
6. Q: Can the blower be installed vertically?
A: Horizontal mounting is standard; vertical installation is possible but should be verified with our technical team.
7. Q: Does noise increase as the filter gets dirty?
A: Yes, restricted airflow can cause the motor to work harder, increasing both noise and temperature.
8. Q: How much noise reduction does the internal silencer provide?
A: Our built-in sound-absorbing sponge reduces noise levels by approximately 10-15 dB compared to unlined blowers.
9. Q: What is the rated speed of the blower?
A: The standard rotational speed is 2800 rpm at 50Hz and 3400 rpm at 60Hz.
10. Q: Can the blower handle sub-zero inlet air?
A: Yes, provided the air is dry; however, please consult us if the operating environment is below -15°C.