Heavy Duty Iron Casing Industrial Fan
Heavy Duty Iron Casing Industrial Fan

Heavy Duty Iron Casing Industrial Fan

Product Name: 1100W Heavy Duty Iron Casing Industrial Fan
Frequency: 50Hz / 60Hz
Rated Power: 1.1 kW / 1.26 kW
Output Voltage: 380V
Speed: 2800 r/min / 3400 r/min
Max Air Flow: 28 m³/min / 34 m³/min
Max Air Pressure: 2.5 kPa / 2.9 kPa
Noise: 68 dB(A) / 70 dB(A)
Working Temp: <50°C
Duct Inner Diameter: 180 mm
Inlet Diameter: 180 mm
Net Weight: 18 KG
Send Inquiry

Product Details

 

The Heavy Duty Iron Casing Industrial Fan is the most powerful model in the series, delivering 1100 watts of centrifugal airflow through a heavy-duty iron casing designed for the most demanding industrial environments. Product images showcase the substantially built blower with its enlarged spiral housing, reinforced motor mounting bracket, wide-diameter intake with protective mesh, and heavy-gauge steel base plate engineered for vibration absorption during continuous-duty cycles. The dimensional drawings document the larger physical footprint: 500 mm width, 580 mm height, 330 mm depth, and 180 mm intake diameter. Performance specifications confirm 28 cubic meters per minute airflow at 2.5 kPa discharge pressure, operating at 2800 rpm with 68 dB noise output from an 18-kilogram unit. Application scenario graphics demonstrate deployment in industrial-scale manure treatment aeration, multi-lane conveyor drying systems, wide-format printing tunnel forced-air curing, and centralized electronic assembly cleaning stations. The Heavy Duty Iron Casing Industrial Fan incorporates a pure copper motor winding for thermal stability under sustained heavy loads, a dynamically balanced impeller, and reinforced iron housing construction. A structured six-stage OEM customization pathway supports specialized voltage, finish, and accessory configurations. For heavy industrial applications where blower failure means production stoppage, the Heavy Duty Iron Casing Industrial Fan provides the robust construction and power reserves that continuous manufacturing demands.

 

1

2

3

4

5

6

7

8

9

10

11

 

Introduction to application scenarios

 

As the most powerful model in the iron casing series, the Heavy Duty Iron Casing Industrial Fan at 1100 watts serves heavy industrial processing where maximum air volume and pressure determine operational capacity. Large-scale agricultural operations deploy it for industrial manure management - aerating massive storage lagoons where only high-pressure deep-penetration air injection can reach the full waste column. High-volume manufacturing lines use the blower to drive extended air knife arrays spanning wide conveyor systems, drying automotive components, extruded profiles, and sheet metal parts at production speeds. Industrial printing and coating facilities integrate the Heavy Duty Iron Casing Industrial Fan into full-width curing tunnels where the substantial airflow, optionally heated, rapidly processes continuous web materials through multi-stage drying zones. Contract electronics manufacturers employ it for centralized PCB cleaning systems serving multiple assembly lines. The heavy-duty iron casing and copper motor make it suitable for foundry fume extraction, bulk material pneumatic conveying, and large-scale wastewater treatment.

 

14

15

16

17

18

19

20

21

 

Customised processing workflow

 

Getting a customized Heavy Duty Iron Casing Industrial Fan built to your specifications takes six simple steps.

1. Send Requirements: Voltage, frequency, color, logo artwork, and performance needs.

2. Review Quote: Detailed offer within 48 hours including cost, MOQ, and delivery date.

3. Approve Sample: Pre-production unit for physical inspection and formal approval.

4. Place Order: Purchase order with deposit; production slot reserved.

5. Track Production: Weekly status updates with photos; third-party inspection available.

6. Receive Shipment: Tracking information and export documents within 24 hours of departure.

 

22

 

Packaging and transportation

 

23

 

Factory Introduction

 

24

25

26

27

28

29

30

 

FAQ

 

Q: Can the outlet port be rotated or repositioned?

A: The centrifugal housing orientation is fixed during manufacturing. However, we offer two outlet configurations: a flanged interface for bolted duct connections and a smooth cylindrical port for flexible hose attachment. For installations requiring a specific outlet orientation, please specify this during ordering, and we can configure the housing position during assembly.

Q: Can I get the blower in a different color?

A: Yes, custom color finishes are available through our OEM customization service. Standard units are light grey powder-coated. For volume orders, we can match specific RAL or Pantone colors, apply your brand colors, or provide unpainted units for your own finishing process. Minimum order quantities apply for custom colors. Contact our sales team for details.

Q: Do you provide technical support after purchase?

A: Yes, our after-sales team provides support via email, WhatsApp, and video call during business hours (GMT+8). We assist with installation questions, troubleshooting, and application guidance. For complex issues, we can arrange live video inspection of your installation. Spare parts ship within 48 hours of confirmed requirements.

Q: What is the difference between iron case and aluminum case blowers?

A: Iron case blowers offer greater structural rigidity and durability at a more economical price point, making them ideal for fixed installations where weight is not a primary concern. Aluminum case blowers are lighter and naturally corrosion-resistant. Iron case blowers like this medium pressure series are preferred for agricultural, waste treatment, and general industrial applications where rugged construction and cost-effectiveness are prioritized over weight savings.

Q: What voltage options are available?

A: The CF series offers 220V single-phase and 220/380V three-phase configurations at both 50Hz and 60Hz. The 250W, 370W, and 550W models support both single and three-phase. Larger models operate on 380V three-phase. Custom voltage and frequency configurations are available through our OEM customization service.

Q: Can I use this blower for both blowing and suction?

A: The centrifugal blower is primarily designed for pressure (blowing) applications through the outlet port. While the intake does create suction, it is not optimized as a dedicated vacuum pump. For applications requiring strong suction, we recommend our regenerative (side channel) blower series which is specifically engineered for vacuum performance. The CF series excels at medium-pressure forced-air blowing, drying, and aeration.

Q: What accessories and spare parts are available?

A: We stock intake filter meshes, mounting bases, flexible duct connectors, flanged adapters, vibration dampers, external silencers, and replacement impellers. All parts are available for individual purchase. Contact our sales team with your model number for compatibility confirmation, pricing, and availability.

Q: Do you offer international shipping?

A: Yes, we ship globally via sea freight (15-35 days, economical for bulk), air freight (5-10 days), and express courier (3-7 days, DHL/FedEx/UPS). Each blower is individually packed in a reinforced carton with foam cushioning. Multiple units are palletized and shrink-wrapped. All packaging meets international export standards.

Q: Can the blower be used outdoors?

A: The CF series iron casing blower is suitable for sheltered outdoor installations (under a roof or cover). Direct exposure to rain, snow, or standing water should be avoided as the motor and electrical connections are not weather-sealed. For fully exposed outdoor applications, we recommend installing the blower inside a ventilated protective enclosure. Contact us for weatherproofing recommendations.

Q: How do I install the blower?

A: Installation is straightforward: mount the blower on a flat, rigid surface using the four pre-drilled holes in the base plate. Connect the electrical supply according to the wiring diagram on the motor nameplate, ensuring proper circuit protection. Attach ducting or hose to the outlet port. Ensure at least 150mm clearance around the motor for cooling airflow. The intake mesh should remain unobstructed. Detailed installation instructions are included with each unit.

 

Hot Tags: heavy duty iron casing industrial fan, China heavy duty iron casing industrial fan manufacturers, suppliers, factory