Silent Oil Free Ex Proof Vortex Fan
Silent Oil Free Ex Proof Vortex Fan

Silent Oil Free Ex Proof Vortex Fan

Product Name: XGB7500-B Double Stage Explosion-proof Vortex Air Pump
Frequency: 50Hz / 60Hz
Rated Power: 7.5 kW / 8.6 kW
Voltage: 345-415Δ/600-720Y (50Hz), 380-480Δ/660-720Y (60Hz)
Rated Current: 16.7Δ/9.6Y (50Hz), 17.3Δ/10Y (60Hz)
Rated Vacuum: -320 mbar / -350 mbar
Rated Compression: 380 mbar / 400 mbar
Noise Level: 80 dB(A) / 82 dB(A)
Net Weight (N.W): 104.5 kg
Air Duct Diameter: 76 mm
Send Inquiry

Product Details


Cleanliness and quiet operation are typically the first casualties when equipment gets an explosion-proof rating - heavier enclosures amplify noise, and the added motor mass drives designers toward lubricated components. The Silent Oil Free Ex Proof Vortex Fan breaks this pattern by delivering all three attributes - silence, zero oil, and certified explosion safety - in a single dual-stage platform.


At the smallest end of the XGB-B series, the 0.37 kW XGB370-B operates at just 53 decibels, comparable to normal conversation in an office. Achieving this in an explosion-proof motor requires the integrated three-layer silencer system: a high-density sound-absorbing sponge cylinder inside the silencer pipe, a mesh silencer net providing secondary acoustic baffling, and a shock-proof steel base plate isolating residual vibration from the mounting surface. Together, these layers maintain a usable working environment even when the blower runs continuously indoors.


Oil-free operation comes from the regenerative side-channel principle used by all XGB-B models. The dual impellers compress and move air through the pump body without any contact between lubricated surfaces and the working gas stream. A dedicated oil seal isolates the bearing housing's grease cavity from the impeller shaft, creating a permanent physical barrier. The result is a clean airstream suitable for pharmaceutical clean rooms, food-grade grain handling, laboratory gas circulation, and any process where airborne oil contamination would cause product rejection or safety issues.


The silent oil free ex proof vortex fan is chosen for noise and cleanliness-sensitive hazardous applications: hospital chemical storage ventilation, pharmaceutical analytical laboratory fume extraction, food processing plant combustible dust control, research facility inert gas circulation, semiconductor clean-room solvent exhaust, and occupied industrial control room pressurization.


Standard performance envelope: 0.37–5.5 kW (50Hz), three-phase 200–480V dual voltage, 80–500 m³/h airflow, 120–320 mbar maximum discharge, -120 to -300 mbar maximum suction, 53–80 dB noise range. Twenty precision components, individual QC certification, aluminum alloy casting, copper motor winding. Shipped worldwide from Taizhou Yijia's Zhejiang factory - a design-develop-produce integrated manufacturer with daily output of over 8,000 blowers.

 

1

2

3

4

5

6

7

 

Explosion-proof vortex fan performance parameter table & complete machine installation dimension description

 

  • Explosion-proof vortex fan performance parameter table

Product Name

XGB7500-B Double Stage Explosion-proof Vortex Air Pump

Frequency

50Hz / 60Hz

Rated Power

7.5 kW / 8.6 kW

Voltage

345-415Δ/600-720Y (50Hz), 380-480Δ/660-720Y (60Hz)

Rated Current

16.7Δ/9.6Y (50Hz), 17.3Δ/10Y (60Hz)

Rated Vacuum

-320 mbar / -350 mbar

Rated Compression

380 mbar / 400 mbar

Noise Level

80 dB(A) / 82 dB(A)

Net Weight (N.W)

104.5 kg

Air Duct Diameter

76 mm

 

8

 

  • Explosion-proof vortex fan installation dimension description

Model Number

XGB-7500-B

Fan Width (A)

440 mm

Fan Height (B)

510 mm

Fan Length (C)

550 mm

Air Duct Outer Diameter (D)

74.5 mm

Base Plate Side Length (E)

220 mm

Base Plate Side Width (F)

410 mm

Base Plate Side Hole Distance (E1)

172 mm

Base Plate Front Hole Distance (F1)

356 mm

Mounting Hole Diameter (G)

14 mm

 

9

10

 

Introduction to application scenarios


Worker health and safety in hazardous zones are the primary reasons for choosing our explosion-proof vortex air pump. At "work sites" involving tunnels or cramped construction areas, the pump is used for the "removal of toxic gas and local dust," ensuring that workers breathe clean air even in enclosed spaces. A major safety application is "welding gas suction," where the blower extracts the smoke and fine dust generated during welding through a vacuum system, protecting the operator's lungs and eyes from hazardous particulate matter.

 

The pump's "smoke blowing and suction" capability is also used in factories to quickly discharge emitted fumes before they can accumulate and pose a fire or health risk. For environmental protection, the blower is integrated into "gas decomposition" devices, attracting and moving harmful gases through buckets and filters for treatment. Even in specific machines like "ironing machines," the pump plays a safety role by sucking out hot steam, preventing the workspace from becoming dangerously humid or overheated. By using professional glands and rubber seals at the wiring ports, the pump itself remains a safe, non-ignition source in these gas-laden environments, providing a comprehensive safety solution for modern industry.

 

11

12

13

14

15

16

17

18

 

Custom processing flow


Bring us your technical drawings, and we will handle the rest. Our integrated design-develop-produce model starts with expert sample processing and a competitive factory quote. We ensure that lead times are realistic during the sample confirmation phase. Mass production orders are processed immediately upon payment, utilizing our in-house motor winding and die-casting facilities. Our transaction completion involves a professional hand-off and quality verification, making us the preferred OEM partner for buyers in over 60 countries.

 

19

 

Packaging and transportation

 

20

 

Factory introduction

 

21

22

23

24

25

26

27

 

FAQ

 

1. Q: How easy is it to install the blower?

A: Our units feature a compact design with a pre-drilled shock-proof base plate for straightforward bolting.

2. Q: Are the air ports labeled for direction?

A: Yes, clear directional arrows on the pump casing indicate the correct inlet and outlet flow.

3. Q: Is the wiring junction box accessible?

A: Yes, it is located on top of the motor for easy access and features a professional fan wiring diagram inside the lid.

4. Q: What kind of cabling is required?

A: We recommend using high-quality industrial cable through our professional glands for an airtight seal.

5. Q: Does the paint chip easily?

A: No, our phosphated surface treatment and electrostatic spray painting create a very durable, uniform coating.

6. Q: Can the blower be mounted vertically?

A: While horizontal mounting is standard, please consult our technical team if your installation requires a vertical orientation.

7. Q: Is there a handle for moving the small models?

A: The structural fins provide a secure grip, and the lightweight aluminum housing makes the smaller units quite portable.

8. Q: How do I know the unit is working correctly at startup?

A: A quiet, vibration-free 2800 rpm spin and steady airflow indicate a successful startup.

9. Q: Is the fan cover removable for cleaning?

A: Yes, the fan cover is secured with screws and can be removed to clear any obstructions from the cooling fan.

10. Q: Are the safety labels provided in English?

A: Yes, all warning labels regarding electrical safety and impurities are provided in standard English.

 

Hot Tags: silent oil free ex proof vortex fan, China silent oil free ex proof vortex fan manufacturers, suppliers, factory