220V High Pressure Double Stage Fan
220V High Pressure Double Stage Fan

220V High Pressure Double Stage Fan

Product Name: 2XGB 420H36 Double Stage Vortex Air Pump
Frequency: 50Hz / 60Hz
Rated Power: 1.5 kW / 2.05 kW
Output Voltage: 220-240Δ345-415Y / 220-275Δ380-480Y
Rated Current: 7.5/4.3 Y / 7.6/4.4 Y
Max Air Flow: 150 m³/h / 180 m³/h
Max Vacuum: -280 mbar / -320 mbar
Max Pressure: 280 mbar / 310 mbar
Noise: 66 dB(A) / 69 dB(A)
Weight: 25 Kg
Send Inquiry

Product Details


Not every high-stakes air handling task has access to industrial three-phase power, making the 220V High Pressure Double Stage Fan a vital tool for small factories, laboratories, and specialized workshops. Designed to plug into standard 220V grids, this 220V High Pressure Double Stage Fan utilizes two series-mounted aluminum impellers to achieve pressure levels that far exceed standard single-stage fans. The compact 20-part precision assembly is powered by a high-torque copper coil motor, ensuring stable 2800 rpm rotation and sustained pneumatic force for vacuum holding or air-knife drying tasks.


The 220V High Pressure Double Stage Fan maintains a professional quiet profile (55-60dB) thanks to its integrated silencer duct and sound-absorbing sponge. The precision-machined aluminum alloy shell provides excellent fire and corrosion resistance, while the C&U bearings are rated for 180°C high-temperature endurance. Every unit is manufactured at Yijia's 2,550m2 Taizhou facility and undergoes individual dynamic balance testing. With its oil-free regenerative principle, this 220V model provides a hygienic and reliable pneumatic solution for pharmaceutical labs and food packaging lines. We support worldwide shipping and OEM labeling, delivering factory-direct high-pressure performance for global single-phase industrial needs.

 

1

bb8cbc92-2515-40cd-9698-1b0b04d161a0.jpg

3

4

5

6

7

8

9

 

Twin impeller vortex fan parameter table & complete machine installation dimensions explanation

 

  • Twin impeller vortex fan performance parameter table

Product Name

2XGB 420H36 Double Stage Vortex Air Pump

Frequency

50Hz / 60Hz

Rated Power

1.5 kW / 2.05 kW

Output Voltage

220-240Δ345-415Y / 220-275Δ380-480Y

Rated Current

7.5/4.3 Y / 7.6/4.4 Y

Max Air Flow

150 m³/h / 180 m³/h

Max Vacuum

-280 mbar / -320 mbar

Max Pressure

280 mbar / 310 mbar

Noise

66 dB(A) / 69 dB(A)

Weight

25 Kg

 

10

 

  • Twin impeller vortex fan installation dimensions explanation

11

12

13

 

Application scenarios introduction

 

High-speed textile production generates significant amounts of scrap fabric and lint. Our vortex fans are deployed to "blow away paper and cloth strips," using a high-velocity air stream to move trimmings from the cutter head to collection filters. In weaving mills, "weaving machine suction wire" tasks remove excess thread and moisture, ensuring the fabric remains clean and free of defects. For the finishing of heavy garments, the blower is integrated into "ironing machines" to suck out hot steam and moisture, preventing dampness and accelerating the drying cycle. The blower's low-noise design and 180°C rated bearings ensure it can thrive in the dense, high-temperature environment of modern garment factories.

 

14

15

16

17

18

19

20

21

 

Custom processing workflow

 

22

 

Packaging and transportation

 

23

 

Factory introduction

 

24

25

26

27

28

29

30

 

FAQ

 

1. Q: What size are the inlet and outlet ports?

A: Port sizes range from 1.5 inch (40mm) to 4 inch (118mm) depending on the motor power.

2. Q: Do I need special tools to install the blower?

A: No, standard wrenches are sufficient to bolt the base plate and connect the flange threads.

3. Q: Can I use flexible hose for the connections?

A: Yes, industrial-grade flexible hose is excellent for reducing vibration transfer to the piping system.

4. Q: Should I install a pressure gauge?

A: Yes, we highly recommend a gauge to monitor the system and ensure the blower stays within its rated range.

5. Q: How far away can the blower be from the application point?

A: It can be several meters away, but keep pipe bends to a minimum to reduce friction loss.

6. Q: Is a check valve necessary?

A: For aeration and liquid agitation, a check valve is vital to prevent water from siphoning back into the blower.

7. Q: Does the blower need a dedicated foundation?

A: A level, solid surface (concrete or heavy steel frame) is sufficient thanks to the shock-proof base.

8. Q: Are the ports threaded?

A: Yes, most models feature standard female threads (G or NPT) for easy plumbing integration.

9. Q: Can I mount the blower upside down?

A: We do not recommend this as it may affect cooling and bearing lubrication distribution.

10. Q: Is it easy to integrate into a PLC control system?

A: Yes, the 3-phase motor can be easily managed via a standard industrial contactor or inverter.

 

Hot Tags: 220v high pressure double stage fan, China 220v high pressure double stage fan manufacturers, suppliers, factory